建筑技术
 
 
建筑技术  2013, Vol. 44 Issue (8): 735-738    DOI:
试验研究 最新目录 | 下期目录 | 过刊浏览 | 高级检索
装配式插销脚手架结构性能试验
ASSEMBLY BOLT SCAFFOLD PERFORMANCE EXPERIMENT
 全文: PDF (756 KB)   HTML (1 KB)  输出: BibTeX | EndNote (RIS)      背景资料
摘要 对4种不同高宽比的装配式脚手架支承结构做静力加载试验,总结其破坏方式,结果表明:立杆插接缺陷和等效水平荷载是造成结构破坏的主要原因。根据结构的极限荷载和立杆的水平位移,确定了格构柱的水平荷载系数及立杆极限承载力对高宽比的折减系数。通过有限元比较,验证了水平荷载系数和高宽比折减系数的准确性。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
刘 伟
杨庆山
王 玉
关键词装配式脚手架   水平荷载系数   高宽比     
Abstract: Four types of assembly scaffold supporting system were tested in static loading. All these failures are mainly caused by pole plug-defect and Equivalent horizontal load. By measuring the ultimate load and horizontal displacement of a single pole, this paper determines horizontal load factor and reduction factor of pole’s ultimate capacity by Height-width ratio. Compared with the finite element, the horizontal load factor and reduction factor on height-width ratio is proved to be accurate.