COMPARISON ON ESTIMATION METHOD FOR EFFECTIVE AREA OF THIN-WEBBED BOX-SHAPED MEMBER
GUO Yan-li1, YAO Xing-you2
1. College of Engineering, Guangdong Ocean University,524088,Zhanjiang, Guangzhou, China; 2. College of Civil Engineering, Tongji University,200092, Shanghai, China
Abstract:
So the methods estimated of effective width of code for design of steel structures (GB50017-2003), technical code of cold-formed thin-wall steel structures(GB50018-2002), America specification (AISC: 2005),European specification(E3-1.5:2006), and Winter equation are introduced in this paper. The effective area of thin-webbed box members with different width-thickness ratio in web and flange are estimated using these codes. Comparison on these estimated results show that European specification(E3-1.5:2006) and Technical code of cold-formed thin-wall steel structures(GB50018-2002)is application for members with different width-thickness ratio of web and flange . So Technical code of cold-formed thin-wall steel structures (GB50018-2002) can be used to estimate the effective area of thin-webbed box members.
GUO Pan-Li,TAO Hang-You. COMPARISON ON ESTIMATION METHOD FOR EFFECTIVE AREA OF THIN-WEBBED BOX-SHAPED MEMBER[J]. Architecture Technology, 2011, 42(05): 467-469.