Abstract:
Double glass curtain wall design of green demonstration building of Logistical Engineering University of PLA is introduced and four different double glass curtain wall systems are compared after analog calculation and quantitative analysis based on differences in materials and types of glass curtain wall in summer. It is discovered that indoor heat obtainment will be obviously decreased in summer after transmittivity of glass is reduced.
LI Meng,HU Wang-she,YANG Yue et al. ANALYSIS ON HEAT TRANSFER EFFICIENCY OF DOUBLE GLASS CURTAIN WALL
IN SUMMER OF CHONGQING[J]. Architecture Technology, 2012, 43(4): 307-309.