摘要 基于Perform-3D软件,输入3条地震波对工程实例进行动力弹塑性分析,以ASCE 41规定的构件弹塑性变形量化指标作为可接受准则,对工程实例进行抗震性能评估,结果表明在罕遇地震作用下结构刚度降低有限,结构处于弱非线性状态;层间位移角等性能指标均满足规范要求,满足“强柱弱梁”等设计要求;剪力墙、框架梁(连梁)等构件比预期性能目标好,结构处于运行控制性能阶段,有较多的安全储备。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
舒林
谭继可
贾善坡
关键词抗震性能评估   动力弹塑性分析   Perform-3D     
Abstract:  Based on the Perform-3D software, the dynamic nonlinear analysis is carried out for the engineering example by inputting three seismic waves. The seismic performance of an engineering example is assessed based on Perform-3D which refer to the acceptable criteria of elastoplastic deformation of ASCE 41. The dynamic nonlinear analysis results show that few structure stiffness to reduce under rare occurred earthquakes, and the structure in the weakly nonlinear state. The elastoplastic floor drifts and other performance targets are qualified to specification requirements. The structure meets specification “column is better than beam” and other related anti-seismic concept design requirements. And it is concluded that shear wall, frame beam, frame column, conversion truss were better than expected performance goals. The structure has a larger safety reserve, and the performance stage of structure is IO.
Key wordsseismic performance assessment   dynamic nonlinear analysis   Perform-3D   
引用本文:   
舒林,谭继可,贾善坡. 高层建筑结构抗震性能评估实例[J]. 建筑技术, 2016, 47(4): 371-.
SHU Lin,TAN Ji-ke,JIA Shan-po. SEISMIC PERFORMANCE ASSESSMENT OF A HIGH-RISE BUILDING STRUCTURE[J]. Architecture Technology, 2016, 47(4): 371-.
链接本文:  
http://www.jzjs.com/CN/     或     http://www.jzjs.com/CN/Y2016/V47/I4/371
 
没有找到本文相关图表信息
没有本文参考文献
[1] 刘 冰. 大连某超高层框架-核心筒-伸臂结构整体设计[J]. 建筑技术, 2015, 46(7): 661-.
?
版权所有 © 2011 建筑技术杂志社
地址:北京市广莲路1号建工大厦A座9层,邮编100055 电话:(010)68512449 (010)63928687,63928688 e-mail:jzjs@sina.com
本系统由北京玛格泰克科技发展有限公司设计开发 技术支持:support@magtech.com.cn