Abstract:
Limitations of radiance and energy consumption simulation are existed as many styles. Radiance is coupled with EnergyPlus in this paper. The case is made by Rhino which using Preze sky model. The annual dynamic radiance and energy consumption simulation is based on local weather. Use a building as an example to test this simulation method.The result shows that the radiance decreasing as the depth increasing. The quality of radiance is best in example T2 between 100~2 000 lux. Heating energy consumption of four examples are more than 83% of total energy. The heating energy of example T1 is the highest but with the lowest total energy consumption.
SHI Tie-mao,WU Zi-jing,XIA Xiao-dong et al. RESEARCH ON SIMULATION METHOD FOR ANNUAL CLIMATE-BASED DYNAMIC DAYLIGHTING & ENERGY COMSUMPTION[J]. Architecture Technology, 2016, 47(11): 966-.