Abstract:
Steel plate-concrete composite shear wall has strong bearing capacity and excellent energy dissipation, giving a full joint play of both steel plate and concrete. Based on the force bearing mechanism, this paper introduced the calculation method for bearing capacity of steel plate-concrete composite shear wall, and used finite-element method to analyze the influence of concrete slab thickness, height-thickness ratio of steel plate and span-depth ratio on the bearing capacity of composite shear wall.
LIU Xiang,WU Wen. Study on Bearing Capacity and Application of Steel Plate-Concrete Composite Shear Wall[J]. Architecture Technology, 2017, 48(9): 987-.