Abstract:
HCSA-R hydration heat inhibitable thermal shrinkage-drying shrinkage full compensation concrete was taken as the core anti-crack technique. "Internet+" monitoring technology was also used as assistance, such as the whole deformation, strain and temperature for cementitious materials, to solve the cracking problems of the wall test section of capital new airport. Results show that the application of anti-cracking significantly improves the anti-crack ability of the wall. The whole hydration heat of test section concrete level off, and the peak temperature rise decreases 10.4ºC. above all the cracking rate of wall reduce 90%.
LEI Su-su1,JIA Fu-jie2,LI Jian-hua1 et al. Application of Anti-Crack Technology in the Wall Test Section of Capital New Airport[J]. Architecture Technology, 2018, 49(9): 934-.