Abstract:
The steel mesh frame and the electromechanical system are integrated with the overall hydraulic lifting, and there are few engineering examples. Based on the finite element analysis of the integrated lifting electromechanical system of steel grid, this paper deeply discusses the influence of the vertical deformation of the grid on the material in the electromechanical system after loading the electromechanical system of the steel grid, thus determining the integrated electromechanical system of the steel grid. Integrated and enhanced construction plan. The technical solution was applied in the new main
exhibition hall project of Zhuhai Airshow Center, and the construction task was successfully completed.
ZHANG Jian-zhong,Li Xin-yan,Xu Zhuo et al. Research on integrated lifting technology of integrated electromechanical
system for large-area bolt-and-ball grid[J]. Architecture Technology, 2018, 49(12): 1268-.